320/ft² (29.73/m²) per Pail @ 0.75 mm (29.53 mils)
AirStop Water Resistive Barrier Barrier/Air Barrier is a waterborne coating with multi-function features that can be spray or trowel-applied
- Highly flexible, bridges crack which may form in the substrate
- Vapour permeable, minimizes risk of condensation in the wall from water vapour diffusion
- Liquid application assures a monolithic, seamless membrane
- Water resistive (WRB) air barrier membrane & tie-In membrane
- Exceptional adhesion to Oriented Strand Board sheathing (OSB), Plywood, expanded and extruded polystyrene
- Self-seals around nails, forming a tight, seamless barrier against water and air leakage
AirStop is intended to be used as a Water Resistive Barrier/Air Barrier within the building envelope. When used in combination with Barrier Seam Tape, AirStop provides the continuity of the WRB/Air barrier around window and door rough openings and functions as well as a tie-in membrane over window flanges and door jambs, providing easier application and lowering installation costs than other conventional products (i.e. butyl flashing tapes or plastic sill pans).
AirStop can be applied to most common surfaces such as concrete, brick, concrete block, glass-mat coated gypsum, cement board, Plywood and Oriented Strand Board (OSB) and integrated into various Durex® EIF Systems for both new and retrofit construction.
Product Type | Water-based copolymer | |
Appearance | Red viscous material in its liquid state | |
Specific Gravity | 1.36 | |
ph Level | 8.5 | |
Application Temperature | Above 2°C (35°C) | |
Coverage | 30-35m² (320-370ft²)/pail @ 0.75 mm (0.030") WFT |
Method | Results | |
---|---|---|
Bond Strength | ASTM C297 |
|
Tensile Strength | ASTM D412 | 1.10 MPa (160 psi) |
Elongation | ASTM D412 | 450% elongation at break |
Joint Disruption Resistance | CCMC E.1-16 | PASS 2mm & 4mm Joints (deflection up to L/180) |
Nail Sealability | ASTM D1970 | PASS @ 1.4mm(0.055”) & 1.0mm(0.040”) & 0.75mm(0.030”) WFT |
Air Leakage | - CAN/ULC S741-08 (Standard for Air Barrier Materials)
-ASTM E-2178-13 (Standard Test Method for Air Permeance of Building Materials) | PASS requirement <0.002 L/(s.m2) @ 75 Pa Actual 0.0015L/(s.m2) @ 75 Pa @ 0.57mm (0.023”) DFT PASS requirement <0.002 L/(s.m2) @ 75 Pa Actual 0.0015L/(s.m2) @ 75 Pa @ 0.57mm (0.023”) DFT |
Water Vapour Permeance | ASTM E96 | Thickness Method A Method B @ 1.4mm 115 ng/Pa.s.m2 331 ng/Pa.s.m2 (0.055”) WFT (2 perms) (5.8 perms) @ 1.0 mm 136 ng/Pa.s.m2 344 ng/Pa.s.m2 (0.040”) WFT (2.4 perms) (6 perms) @0.75 mm 185 ng/Pa.s.m2 505 ng/Pa.s.m2 (0.030”) WFT (3.2 perms) (8.8 perms) |
Coefficient of Water Absorption | CCMC 5.5.1 | 0.0001 kg/m2.s1/2 @ 0.75mm (0.030”) |