IBS Equalite Select combines all of the features of the Durex® IBS Quantum plus the the feature of being 100% Non-Combustible. As a prefabricated Curtain Wall System it combines all of the durability essentials of environmental separation controls of heat / air / moisture / fire, strength, durability and aesthetics performance features of the EPS Based Durex IBS Quantum Select plus the fire safety of 100% non-combustible components. Making it the only fully approved code compliant system in its class. It brings significant advancements to the conventional, architecturally limited, glass, stone or other material curtain walls through a water-managed, pressure-moderated and energy efficient wall system.
- Pre-engineered Lightweight Panel Design
- Totally Non-Combustible Panel System
- Pressure Moderated Rain Screen Design
- Air/Water tight Building Envelope Design
- Geometrically Defined Drainage Cavity (GDDC)
- Superior Thermal Performance
- 1 Hour Fire Rated System ULC W-489
- 2-Hour Fire Rated System ULC W-485
- Continuous Insulation - (CI) Factor = 0.76 RSI/in
IBS Equalite Select is the only choice when non-combustibility is a must, whether by design and / or code requirements. It provides the best wall solution in a controlled prefabricated approach that guaranties quality control and speed of construction. Equally applicable for all types of construction, be it institutional, residential, commercial, industrial and/or temporary. IBS’s lightweight and flexibility make it an ideal solution for applications in high seismic/wind zones.
Building Code Conformance | Classification |
Category 1 CAN/ULC S114 |
|
Part 3 |
|
|
|
Part 4 |
|
|
|
Part 5 |
|
|
|
Part 9 |
|
|
|
INSULATION: |
Durex Equalite Select Mineral Fiber |
CAN/ULC S702 |
Thermal Resistance GDDC Factor 0.70 RSI (R 4.0) per inch 25% |
WATER RESISTIVE BARRIER: | Air / Vapour Barriers Durex Flexseal Air Barriers Durex Flexseal VP Durex AirStop |
ASTM E96 –Water Vapour Transmission (Refer to product specific Technical Data Sheet for more detailed data) |
Method A Method B 2.9 ng/Pa.s.m2
629 ng/Pa.s.m2 972 ng/Pa.s.m2 185 ng/Pa.s.m2 505 ng/Pa.s.m2 |
INSULATION ATTACHMENT: | -Durex“M” fasteners (masonry) -Durex “W” fasteners (wood) -Durex “S” fasteners (steel) -Durex Equalite Washer NC |
ASTM B-117 – salt spray DIN 50012 - SO2 exposure FM4470 & DIN 50018 SFW |
750 hrs. or better 25+ cycles 30 cycles Pass Encapsulated Noncombustible Metal Plate |
LAMINA: | Impant Resistance Durex Fiberglass Mesh (Note: Impact resistance level is directly related to the weight and layers of Fiberglass mesh used in the lamina) |
ASTM E2486 – Impact Resistance (Refer to Table 1.5.9 of the IBS Equalite Select Specifications for detailed selection chart for guidance on level of impact resistance required) |
Retention Retention Physical Performance Standard 3 N.m 10 N.m PASS Intermediate 8 N.m 15 N.m PASS High 13 N.m 20 N.m PASS Ultra High 20 N.m 30 N.m PASS Extreme 25 N.m 40 N.m PASS |
Base Coat Durex Uniplast/Acrybond “S” Durex Monobase |
CAN/ULC S114 Noncombustibility |
Rated Noncombustible Rated Noncombustible |
|
FINISHES: | Durex Architectural Coatings Classic Series Premium Series Artisan Series Kolor Gard Series Elastomeric (FX) Series |
CAN/ULC S716.1 & CCMC Report # 13103-R (Refer to product specific Technical Data Sheet and CCMC Evaluation Report # 13103-R for more detailed data) |
Durex Architectural Coatings Meet and exceed all requirements |
PERFORMANCE: | Fire Protection |
(Refer CCMC Evaluation Report #13103-R for complete detailed performance data) CAN/ULC S101 & CAN/ULC S114 (Compliance to NBC 3.2.3.8(1) (b) )
CAN/ULC S101 (Fire Resistance rated Assemblies)
CAN/ULC S134 (Compliance to NBC 3.1.5.5) |
Rated as non-combustible cladding ULC design EW21/ EW22
2 hr. FR rating ULC design W425 (Non-Load Bearing) 1 hr. FR rating ULC design W489 (Load Bearing) 2 hrs. FR rating ULC design W485 (Load Bearing) 2 hrs. FR rating ULC design W456 (Non-Load Bearing)
Intertek listing # DPL-WEIFS 30-01 |
Wind Load Resistance |
ASTM E330 – sustained
ASTM E330 – cyclic
ASTM E330 – blow-out |
-2.5 kPa for 60min. – no visible damage to any of the wall components -600 cycles alt. 0 to -2.5kPa – no visible damage to any of the wall components -3.75kPa applied for 10 sec. – no visible damage to any of the wall components - max. pressure 7.12 kPa |
|
Water Tightness |
ASTM E331 |
400 Pa pressure difference for 15 min. – no water penetration through the exterior surface finish |
|
System Compliance |
CCMC Technical Guide for EIFS CAN/ULC S716.1 EIFS Materials & System |
CCMC Evaluation Report # 13103-R Durex IBS Equalite Select is fully compliant with: -CAN/ULC S716.1 Materials & System -CAN/ULC S716.2 Installation of Components & WRB -CAN/ULC S716.3 Design Application |
System Layer | Optional Products Per Layer | Notes |
---|---|---|
Water Resistive Barriers (WRB) | ||
Transition Membranes | ||
Semi Rigid Insulation (Exterior) | Attached with Approved Mechanical Fasteners Attached with Approved Mechanical Fasteners Attached with Approved Mechanical Fasteners |
|
Base Coat | ||
Reinforcing Mesh | ||
Primers | ||
Finishes - Classic Series | ||
Finishes - Premium Series | ||
Finishes - Artisan Series | ||
Finishes - Flexible Series | ||
Finishes - Kolor Gard |