Flexlite Select MF is an exterior insulation and finish system consisting of a moisture barrier, a 10mm geometrically defined drainage cavity, expanded polystyrene insulation, mechanical fasteners, glass fibre-reinforcing mesh, base coats, and a finish texture coat which can be selected from any one of the available Durex Architectural Coatings.
- CAN/ULC S716 compliant
- CCMC evaluated (13103-R)
- Easy installation
- Positive drainage
- Lightweight
- Versatile
- Flexible
- Continuous Insulation – CI Factor = 0.65 RSI/in (Type 1 EPS) 0.7 RSI/in (Type2 EPS)
Flexlite Select MF is primarily suitable for residential work.
Building Code Conformance | Classification |
Category 2 CAN/ULC S134 |
Fire Test of Exterior Wall Assemblies |
Part 3 |
|
|
|
Part 5 |
|
|
|
Part 9 |
|
|
|
INSULATION: |
Durex Flexlite Select Type I Durex Flexlite Select Type II |
ASTM E96 – Water Vapour Transmission |
Thermal Resistance GDDC Factor 0.65 RSI (R 3.9) per inch 15% 0.70 RSI (R 4.0) per inch 15% |
WATER RESISTIVE BARRIER: | Air / Vapour Barriers Durex Flexseal Air Barriers Durex Flexseal VP Durex AirStop |
ASTM E96 – Water Vapour Transmission (Refer to product specific Technical Data Sheet for more detailed data) |
Method A Method B 2.9 ng/Pa.s.m2
629 ng/Pa.s.m2 972 ng/Pa.s.m2 185 ng/Pa.s.m2 505 ng/Pa.s.m2 |
INSULATION ATTACHMENT | -Durex“M” fasteners (masonry) -Durex “W” fasteners (wood) -Durex “S” fasteners (steel) |
ASTM B-117 – salt spray DIN 50012 - SO2 exposure FM4470 & DIN 50018 SFW |
750 hrs. or better 25+ cycles 30 cycles Pass |
LAMINA: | Impant Resistance Durex Fiberglass Mesh (Note: Impact resistance level is directly related to the weight and layers of Fiberglass mesh used in the lamina) |
ASTM E2486 – Impact Resistance (Refer to Table 1.5.9 of the Flexlite Select MF Specifications for detailed selection chart for guidance on level of impact resistance required) |
Retention Retention Physical Performance Standard 3 N.m 10 N.m PASS Intermediate 8 N.m 15 N.m PASS High 13 N.m 20 N.m PASS Ultra High 20 N.m 30 N.m PASS Extreme 25 N.m 40 N.m PASS |
Base Coat Durex Monobase Durex Flexcrete |
CAN/ULC S114 Noncombustibility |
Rated Noncombustible |
|
FINISHES: | Durex Architectural Coatings Classic Series Premium Series Artisan Series Kolor Gard Series Elastomeric (FX) Series |
CAN/ULC S716.1 & CCMC Report # 13103-R (Refer to product specific Technical Data Sheet and CCMC Evaluation Report # 13103-R for more detailed data) |
Durex Architectural Coatings Meet and exceed all requirements |
PERFORMANCE: | Fire Protection |
(Refer CCMC Evaluation Report # 13103-R for complete detailed performance data) CAN/ULC S134 (Compliance to NBC 3.1.5.5) |
Intertek listing # DPL-WEIFS 30-01 |
Wind Load Resistance |
ASTM E330 – sustained
ASTM E330 – cyclic
ASTM E330 – blow-out |
-2.5 kPa for 60min. – no visible damage to any of the wall components -600 cycles alt. 0 to -2.5kPa – no visible damage to any of the wall components -3.75kPa applied for 10 sec. – no visible damage to any of the wall components - max. pressure 7.12 kPa |
|
Water Tightness |
ASTM E331 |
400 Pa pressure difference for 15 min. – no water penetration through the exterior surface finish |
|
System Compliance |
CCMC Technical Guide for EIFS CAN/ULC S716.1 EIFS Materials & System |
CCMC Evaluation Report # 13103-R Durex Flexlite Select MF is fully compliant with: CAN/ULC S716.1 Materials & System CAN/ULC S716.2 Installation of Components & WRB CAN/ULC S716.3 Design Application |
System Layer | Optional Products Per Layer | Notes |
---|---|---|
Water Resistive Barriers (WRB) | ||
Transition Membranes | ||
Rigid Insulation (Exterior) | Attached with Approved Mechanical Fasteners Attached with Approved Mechanical Fasteners Attached with Approved Mechanical Fasteners |
|
Base Coat | ||
Reinforcing Mesh | ||
Primers | ||
Finishes - Classic Series | ||
Finishes - Premium Series | ||
Finishes - Artisan Series | ||
Finishes - Flexible Series | ||
Finishes - Kolor Gard |