Insulite Select MF
Advanced Thermal Resistance Drained & Moisture Managed EIFS (Mechanically Fastened)
Description

Insulite Select MF is a pressure moderate, Geometrically Defined Drainage Cavity (GDDC) Exterior Insulation and Finish System that includes a water resistive barrier, or optional air/vapour barrier applied to the substrate to act as a secondary moisture barrier.

Advantages
  • Positive drainage (through a network of vertical and horizontal channels)
  • Continous air/vapour barrier
  • Simple interfacing with other pressure equlized
  • Lightweight
  • Economical
  • Aethetic design flexibility
Uses

Insulite Select MF is suitable for use over a wide range of structurally sound substrates and is recommended for use on buildings where the Building Code allows the use of fire-tested wall assemblies which include combustible foam plastic insulation.

Performance Properties
Building Code Conformance

Classification

Category 1

CAN/ULC S114 & CAN/ULC S101

CAN/ULC S134

 

Non-Combustible Lamina

Fire Test of Exterior Wall Assemblies

Part 3

  • Article 3.1.5.5
  • Article 3.1.5.2
  • Article 3.2.3.7 & Table 3.2.3.7
  • Sub-Section 3.2.3.8 (1) (b)
  • Combustible Cladding on Exterior Walls
  • Allowable Minor Combustible Components
  • >10% Unprotected Openings
  • CAN/ULC S101-15 minutes- Non-Combustible Base Coat

Part 5

  • Section 5.6.1
  • Sub-Section 5.6.2.1
  • Section 5.9.4
  • Protection from Precipitation
  • Sealing and Drainage
  • Exterior Insulation Finish Systems

Part 9

  • Clause 9.25.2.2(1)(d)
  • Sub-Section 9.25.5.2
  • Clause 9.27.1.1(5)
  • Section 9.27.2
  • Article 9.27.3.1
  • Sub-Section 9.27.13
  • Article 9.10.14.5 & Table 9.10.14.5 (A)
  • Article 9.10.15.5
  • Insulation Materials  CAN/ULC S701
  • Position of Low Permeance Membranes
  • General (Cladding, Application)
  • Required Protection from Precipitation
  • Elements of Second Plane of Protection
  • Exterior Insulation Finish Systems
  • >10% Unprotected Openings
  • >0.6 m Limiting Distance
INSULATION:

 

Durex Insulite Select Graphite EPS

 

CAN/ULC S701

Thermal Resistance                 GDDC Factor

0.76 RSI  (R 4.2) per inch                  25%

WATER RESISTIVE BARRIER:

 Air / Vapour Barriers

  Durex Flexseal

Air Barriers

  Durex Flexseal VP

  Durex AirStop

 

ASTM E96   – Water Vapour Transmission

(Refer to product specific Technical Data Sheet for more detailed data)

Method A                              Method B

                                               2.9 ng/Pa.s.m2

 

629 ng/Pa.s.m2                              972 ng/Pa.s.m2

185 ng/Pa.s.m2                              505 ng/Pa.s.m2

INSULATION ATTACHMENT:

-Durex“M” fasteners (masonry)

-Durex “W” fasteners (wood)

-Durex “S” fasteners (steel)

ASTM B-117 – salt spray

DIN 50012 - SO? exposure

FM4470  &   DIN 50018 SFW

750 hrs. or better

25+ cycles

30 cycles  Pass

LAMINA:

Impant Resistance

Durex Fiberglass Mesh

(Note: Impact resistance level is directly related to the weight

and  layers of Fiberglass mesh

used in the lamina

 

ASTM E2486 – Impact Resistance

(Refer to Table 1.5.9 of the Insulite Select MF

Specifications for detailed selection chart for

guidance on level of impact resistance required)

                      Retention           Retention         

                      Physical             Performance

Standard       3 N.m                  10 N.m      PASS

Intermediate  8  N.m                 15 N.m      PASS

High              13 N.m                 20 N.m     PASS

Ultra High      20 N.m                30 N.m      PASS

Extreme        25 N.m                 40 N.m     PASS

Base Coat

  Durex Uniplast/Acrybond “S”

  Durex Monobase

  Durex Flexcrete

 

CAN/ULC S114  Noncombustibility

 

Rated Noncombustible

Rated Noncombustible

 

FINISHES:

Durex Architectural  Coatings

   Classic Series

   Premium Series

   Artisan Series

   Kolor Gard Series

   Elastomeric (FX) Series

 

CAN/ULC S716.1   &

CCMC Report #  13103-R

 

(Refer to product specific Technical Data

Sheet and CCMC Evaluation Report

#13103-R for more detailed data)

 

Durex Architectural Coatings

Meet and exceed all requirements

PERFORMANCE:

  Fire Protection

(Refer CCMC Evaluation Report # 13103-R for

complete detailed performance data)

CAN/ULC S101 & CAN/ULC S114

(Compliance to NBC 3.2.3.8(1) (b) )

CAN/ULC S101

 (Fire Resistance rated Assemblies)

 

CAN/ULC S134

(Compliance to NBC 3.1.5.5)

 

 

Rated as non-combustible cladding ULC design EW21/ EW22

 

1 hr. FR rating ULC design  W489 (Load Bearing)

2 hrs. FR  rating ULC design W485 (Load Bearing)

2 hrs. FR rating ULC design W456 (Non-Load Bearing)

Intertek  listing  # DPL-WEIFS 30-01

Wind Load Resistance

ASTM E330    – sustained

 

ASTM E330    – cyclic

 

ASTM E330    – blow-out

-2.5 kPa for 60min. – no visible damage to any of the wall components

-600 cycles alt. 0 to -2.5kPa – no visible damage to any of the wall components

-3.75kPa applied for 10 sec. – no visible damage to any of the wall components - max. pressure 7.12 kPa

Water Tightness

ASTM E331

400 Pa pressure difference for 15 min. –  no water penetration through the  exterior surface finish

System Compliance

CCMC Technical Guide for EIFS

CAN/ULC S716.1 EIFS Materials & System

CCMC Evaluation Report # 13103-R

Durex Insulite Select MF is fully compliant with:

-CAN/ULC S716.1  Materials & System

-CAN/ULC S716.2 Installation of Components & WRB

-CAN/ULC S716.3 Design Application

System Layer Optional Products Per Layer Notes
Water Resistive Barriers (WRB)
Transition Membranes
Rigid Insulation (Exterior)
Attached with Approved Mechanical Fasteners
Attached with Approved Mechanical Fasteners
Attached with Approved Mechanical Fasteners
Base Coat
Reinforcing Mesh
Primers
Finishes - Classic Series
Finishes - Premium Series
Finishes - Artisan Series
Finishes - Flexible Series
Finishes - Kolor Gard