Equalite
Noncombustible Pressure Equalized Mineral Fiber Insulation Finish System
Description

Equalite is a pressure equalized exterior insulation and finish system. The system, which has been independently tested, consists of a membrane air/vapour barrier, mineral fibre insulation, mechanical fasteners, glass fibre reinforcing mesh, continuous vent boards, non-combustible base coats, and a finish texture coat from any one of the available Durex® Architectural Coatings.

Advantages
  • Totally non-combustible cladding
  • Pressure equalized (drained & vented principle)
  • Continuous venting at floor lines and horizontal terminations
  • Vertical orientation of the fibres in the rigid insulation allows for positive drainage
  • Continuous water resistive barrier (self-sealing)
  • Simple interfacing with other pressure equalized cladding systems
  • Continuous high density thermal barrier
  • Aesthetic design flexibility
  • Continuous Insulation – CI Factor = 0.70 RSI/in.
Uses

Equalite is suitable for use over a wide range of structurally sound substrates and is recommended for use in buildings which require to be of non-combustible construction and pressure equalized cladding.

Performance Properties
Building Code Conformance:

Classification

Category 1 CAN/ULC S114

  • NON-COMBUSTIBLE SYSTEM
  • Non-Combustible Lamina
  • Non-Combustible Insulation

Part 3

  • Article 3.1.5.1
  • Article 3.1.5.2
  • Article 3.2.3.7 & Table 3.2.3.7
  • Non-Combustible System
  • Allowable Minor Combustible Components
  • 0-10% Unprotected Openings

Part 5

  • Section 5.6.1
  • Sub-Section 5.6.2.1
  • Section 5.9.4
  • Protection from Precipitation
  • Sealing and Drainage
  • Exterior Insulation Finish Systems

Part 9

  • Clause 9.25.2.2(1)(d)
  • Sub-Section 9.25.5.2
  • Clause 9.27.1.1(5)
  • Section 9.27.2
  • Article 9.27.3.1
  • Sub-Section 9.27.13
  • Article 9.10.14.5 & Table 9.10.14.5 (A)
  • Article 9.10.15.5
  • Insulation Materials  CAN/ULC S701
  • Position of Low Permeance Membranes
  • General (Cladding, Application)
  • Required Protection from Precipitation
  • Elements of Second Plane of Protection
  • Exterior Insulation Finish Systems
  • 0-10% Unprotected Openings
  • < 0.6 m Limiting Distance
INSULATION:

 

Durex Equalite   Mineral Fiber

 

CAN/ULC S702

Thermal Resistance                    GDDC Factor

0.70 RSI  (R 4.0) per inch                  -----

WATER RESISTIVE BARRIER:

 Air / Vapour Barriers

  Durex Flexseal

Air Barriers

  Durex Flexseal VP

  Durex AirStop

 

ASTM E96 –Water Vapour Transmission

(Refer to product specific Technical Data Sheet

for more detailed data)

Method A                              Method B

                                               2.9 ng/Pa.s.m2

 

629 ng/Pa.s.m2                              972 ng/Pa.s.m2

185 ng/Pa.s.m2                              505 ng/Pa.s.m2

INSULATION ATTACHMENT:

-Durex“M” fasteners (masonry)

-Durex “W” fasteners (wood)

-Durex “S” fasteners (steel)

-Durex Equalite Washer NC

ASTM B-117 – salt spray

DIN 50012 - SO2 exposure

FM4470  &   DIN 50018 SFW

750 hrs. or better

25+ cycles

30 cycles  Pass

Encapsulated Noncombustible Metal Plate

LAMINA:

Impant Resistance

Durex Fiberglass Mesh

(Note: Impact resistance level is directly related

to the weight and  layers of Fiberglass mesh used in the lamina)

 

ASTM E2486 – Impact Resistance

(Refer to Table 1.5.9 of the Equalite  Specifications for

detailed selection chart for guidance on level of impact

resistance required)

                        Retention            Retention         

                        Physical               Performance

Standard            3 N.m                   10 N.m            PASS

Intermediate    8  N.m                   15 N.m            PASS

High                  13 N.m                   20 N.m            PASS

Ultra High        20 N.m                   30 N.m            PASS

Extreme           25 N.m                   40 N.m            PASS

Base Coat

  Durex Uniplast/Acrybond “S”

  Durex Monobase

 

CAN/ULC S114  Noncombustibility

 

Rated Noncombustible

Rated Noncombustible

FINISHES:

Durex Architectural  Coatings

   Classic Series

   Premium Series

   Artisan Series

   Kolor Gard Series

   Elastomeric (FX) Series

 

CAN/ULC S716.1   &

CCMC Report #  13103-R

 

(Refer to product specific Technical Data Sheet and CCMC Evaluation Report # 13103-R for more detailed data

 

Durex Architectural Coatings

Meet and exceed all requirements

PERFORMANCE:

Fire Protection

(Refer CCMC Evaluation Report # 13103-R  for complete detailed performance data)

CAN/ULC S101 & CAN/ULC S114

(Compliance to NBC 3.2.3.8(1) (b) )

CAN/ULC S101

 (Fire Resistance rated Assemblies)

 

CAN/ULC S134

(Compliance to NBC 3.1.5.5)

 

 

Rated as non-combustible cladding ULC design EW21/ EW22

2 hr. FR rating ULC design W425 (Non-Load  Bearing)

1 hr. FR rating ULC design  W489 (Load Bearing)

2 hrs. FR  rating ULC design W485 (Load Bearing)

2 hrs. FR rating ULC design W456 (Non-Load Bearing)

Intertek  listing  # DPL-WEIFS 30-01

Wind Load Resistance

ASTM E330    – sustained

 

ASTM E330    – cyclic

 

ASTM E330    – blow-out

-2.5 kPa for 60min. – no visible damage to any of the wall components

-600 cycles alt. 0 to -2.5kPa – no visible damage to any of the wall components

-3.75kPa applied for 10 sec. – no visible damage to any of the wall components - max. pressure 7.12 kPa

Water Tightness

ASTM E331

400 Pa pressure difference for 15 min. –  no water penetration through the  exterior surface finish

System Compliance

CCMC Technical Guide for EIFS

CAN/ULC S716.1 EIFS Materials & System

CCMC Evaluation Report # 13103-R

Durex Equalite  is fully compliant with:

-CAN/ULC S716.1  Materials & System

-CAN/ULC S716.2 Installation of Components & WRB

-CAN/ULC S716.3 Design Application